{"product_id":"kemo-m013n-dammerungsschalter-licht-sensor-weiss","title":"Kemo M013N Twilight switch 230V AC module 3A potential-free switching contact 10-60 Lux","description":"\u003ch2\u003eKEMO M013N 230 V Twilight Switch Overview\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eKEMO M013N twilight switch\u003c\/strong\u003e is a compact electronic light switch designed for the automatic control of lighting and other suitable loads based on ambient brightness. Using the integrated relay, lighting can, for example, be switched on automatically at dusk and switched off again at daybreak.\u003c\/p\u003e\n\n\u003cp\u003eThis \u003cstrong\u003e230 V twilight switch with a potential-free changeover contact\u003c\/strong\u003e switches resistive loads up to 3 A and inductive loads up to 1 A. Due to its compact design, the module is particularly suitable for permanently installed light control systems where garden, courtyard, driveway, shop window, or advertising lighting is to be switched automatically based on brightness.\u003c\/p\u003e\n\n\u003ch3\u003eAutomatic switching at dusk and daylight\u003c\/h3\u003e\n\n\u003cp\u003eThe integrated light sensor reacts to ambient brightness. The connected load can be switched on at approximately \u003cstrong\u003e10 lux ±50%\u003c\/strong\u003e, while it is switched off at approximately 60 lux ±50%. This allows lighting to be operated automatically without having to switch it manually every evening and morning.\u003c\/p\u003e\n\n\u003ch3\u003eCan also be used with reverse switching function\u003c\/h3\u003e\n\n\u003cp\u003eThe KEMO M013N can do more than just switch on at dark and off at daylight. Thanks to the \u003cstrong\u003epotential-free changeover contact\u003c\/strong\u003e, the reverse function is also possible, meaning a suitable load can be switched on at daybreak and switched off at dusk.\u003c\/p\u003e\n\n\u003ch3\u003e30-second reaction delay\u003c\/h3\u003e\n\n\u003cp\u003eAn integrated \u003cstrong\u003eswitching delay of approx. 30 seconds ±50%\u003c\/strong\u003e prevents short-term changes in ambient brightness from immediately triggering a switching operation. As a result, the twilight switch does not react immediately to transient stray light, for example.\u003c\/p\u003e\n\n\u003ch3\u003ePotential-free changeover contact up to 3 A\u003c\/h3\u003e\n\n\u003cp\u003eThe switching contact is designed as a \u003cstrong\u003epotential-free changeover contact with 1 × SPDT\u003c\/strong\u003e. For resistive loads, the maximum load capacity is 3 A at 230 V, while inductive loads may be switched with a maximum of 1 A.\u003c\/p\u003e\n\n\u003ch3\u003eTypical areas of application\u003c\/h3\u003e\n\u003cul\u003e\n\n  \u003cli\u003eAutomatic control of outdoor lighting\u003c\/li\u003e\n\n  \u003cli\u003eGarden and courtyard lighting\u003c\/li\u003e\n\n  \u003cli\u003eDriveway and garage lighting\u003c\/li\u003e\n\n  \u003cli\u003eShop window lighting\u003c\/li\u003e\n\n  \u003cli\u003eAdvertising systems and displays\u003c\/li\u003e\n\n  \u003cli\u003eAutomatic light control systems\u003c\/li\u003e\n\n  \u003cli\u003eTechnical switching and control projects\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Electronic twilight switch \/ light switch module\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Kemo-Electronic GmbH\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eModel:\u003c\/strong\u003e M013N\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eCurrent consumption:\u003c\/strong\u003e 40 mA\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eSwitching contact:\u003c\/strong\u003e 1 × SPDT changeover, potential-free\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eLoad capacity for resistive load:\u003c\/strong\u003e max. 3 A at 230 V\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eLoad capacity for inductive load:\u003c\/strong\u003e max. 1 A\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eSwitch-on brightness:\u003c\/strong\u003e 10 lux ±50%\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eSwitch-off brightness:\u003c\/strong\u003e 60 lux ±50%\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eReaction delay:\u003c\/strong\u003e 30 seconds ±50%\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eTemperature range:\u003c\/strong\u003e −15 to +40 °C\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eLength:\u003c\/strong\u003e 69 mm\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 59 mm\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 23 mm\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eImportant note\u003c\/h3\u003e\n\n\u003cp\u003eThe light sensor must be mounted in such a way that the \u003cstrong\u003elight from the connected light source does not fall directly onto the twilight switch\u003c\/strong\u003e. Otherwise, the automatic switching function may be impaired.\u003c\/p\u003e\n\n\u003cp\u003eThe integrated reaction delay means the switch does not react immediately to every change in brightness. During installation, the permissible switching currents of a maximum of 3 A for resistive loads or 1 A for inductive loads must also be observed. Work on 230 V mains voltage must be carried out professionally.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhen does the KEMO M013N switch on the lighting?\u003c\/h4\u003e\n\u003cp\u003eThe KEMO M013N switches at an ambient brightness of approximately 10 lux ±50%, making it suitable for automatically activating lighting when it gets dark.\u003c\/p\u003e\n\n\u003ch4\u003eWhen is the connected lighting switched off again?\u003c\/h4\u003e\n\u003cp\u003eThe twilight switch toggles again at an ambient brightness of approximately 60 lux ±50%, allowing the connected lighting to be switched off automatically as daylight increases.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the maximum load for the connected appliance?\u003c\/h4\u003e\n\u003cp\u003eThe potential-free changeover contact can be loaded with a maximum of 3 A at 230 V for resistive loads or with a maximum of 1 A for inductive loads.\u003c\/p\u003e\n\n\u003ch4\u003eWhy does the twilight switch not switch immediately?\u003c\/h4\u003e\n\u003cp\u003eThe KEMO M013N has a reaction delay of approximately 30 seconds ±50% so that short-term changes in ambient brightness do not trigger an immediate switching operation.\u003c\/p\u003e\n\n\u003ch4\u003eCan the twilight switch also switch on during daylight?\u003c\/h4\u003e\n\u003cp\u003eYes, thanks to the potential-free changeover contact, the KEMO M013N can also be connected so that a suitable load is switched on at daybreak and switched off again at dusk.\u003c\/p\u003e","brand":"Kemo-Electronic GmbH","offers":[{"title":"Default Title","offer_id":50521716097354,"sku":"SW3977","price":12.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0918\/9602\/1322\/files\/Kemmo_Germany_M013N_Transformator.webp?v=1788517398","url":"https:\/\/saasil.de\/en\/products\/kemo-m013n-dammerungsschalter-licht-sensor-weiss","provider":"Saasil","version":"1.0","type":"link"}