{"product_id":"b16-3-sicherungsautomat-leitungsschutzschalter-b16-a-sicherung-automat-3-polig-4452","title":"B16 \/3 Miniature Circuit Breaker B16 A Circuit Breaker 3-Pole \/ 4452 | Kanlux S.A.","description":"\u003ch2\u003eKanlux KS6 B16\/3 circuit breaker 3-pole 16 A at a glance\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eKanlux KS6 B16\/3 circuit breaker\u003c\/strong\u003e is a three-pole miniature circuit breaker with a B-type tripping characteristic and a rated current of 16 A. It is used to protect electrical lines and connected loads against \u003cstrong\u003eoverload and short circuits\u003c\/strong\u003e and is suitable for installation in compatible distribution boards and installation systems.\u003c\/p\u003e\n\n\u003cp\u003eWith a breaking capacity of \u003cstrong\u003e6 kA at 230\/400 V AC\u003c\/strong\u003e, three modular spaces, and mounting on a 35 mm DIN rail, this B16 circuit breaker is suitable for corresponding three-phase installations. The design complies with EN 60898 and IEC 60898, respectively, and is intended for indoor use.\u003c\/p\u003e\n\n\u003ch3\u003e3-pole B16 circuit breaker\u003c\/h3\u003e\n\n\u003cp\u003eThe miniature circuit breaker features \u003cstrong\u003ethree coupled poles and a B-type tripping characteristic\u003c\/strong\u003e. This makes it suitable for corresponding three-phase circuits where all three phase conductors are to be protected together by a single circuit breaker.\u003c\/p\u003e\n\n\u003ch3\u003eProtection against overload and short circuits\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e3-pole 16 A circuit breaker\u003c\/strong\u003e protects cables and connected loads from excessively high currents. In the event of an overload or short circuit, the circuit breaker interrupts the affected circuit according to its tripping characteristic.\u003c\/p\u003e\n\n\u003ch3\u003e6 kA breaking capacity and energy limiting class 3\u003c\/h3\u003e\n\n\u003cp\u003eThe breaking capacity is \u003cstrong\u003e6 kA at 230\/400 V AC\u003c\/strong\u003e. Additionally, the circuit breaker is classified as energy limiting class 3 and is designed for appropriate electrical installations according to EN 60898 and IEC 60898, respectively.\u003c\/p\u003e\n\n\u003ch3\u003eMounting on 35 mm DIN rail\u003c\/h3\u003e\n\n\u003cp\u003eThe miniature circuit breaker is intended for \u003cstrong\u003emounting on a 35 mm DIN rail\u003c\/strong\u003e and occupies three modular spaces. This allows it to be integrated into compatible distribution boards and fuse boxes.\u003c\/p\u003e\n\n\u003ch3\u003eTypical areas of application\u003c\/h3\u003e\n\u003cul\u003e\n\n  \u003cli\u003eThree-phase circuits\u003c\/li\u003e\n\n  \u003cli\u003eElectrical distribution boards and sub-distribution boards\u003c\/li\u003e\n\n  \u003cli\u003eResidential and building installations\u003c\/li\u003e\n\n  \u003cli\u003eCommercial electrical installations\u003c\/li\u003e\n\n  \u003cli\u003eControl cabinets and distribution boxes\u003c\/li\u003e\n\n  \u003cli\u003eProtection of electrical lines against overload and short circuits\u003c\/li\u003e\n\n  \u003cli\u003eReplacement for technically compatible B16 circuit breakers\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Circuit breaker \/ Miniature circuit breaker\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Kanlux S.A.\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eModel:\u003c\/strong\u003e KS6 B16\/3\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eNumber of poles:\u003c\/strong\u003e 3-pole\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eTripping characteristic:\u003c\/strong\u003e B\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 16 A\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eRated voltage:\u003c\/strong\u003e 230 V AC\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 50 Hz\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eBreaking capacity at 230\/400 V AC:\u003c\/strong\u003e 6 kA\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eEnergy limiting class:\u003c\/strong\u003e 3\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eModular spaces:\u003c\/strong\u003e 3\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35 mm DIN rail\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eConnection range:\u003c\/strong\u003e 1–25 mm²\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eProtection class:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eAmbient temperature:\u003c\/strong\u003e −5 to +40 °C\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 60898 \/ IEC 60898\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eHousing material:\u003c\/strong\u003e Plastic\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eColor:\u003c\/strong\u003e Light gray\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eSwitch color:\u003c\/strong\u003e Yellow\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eWeight:\u003c\/strong\u003e approx. 230 g\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eArea of application:\u003c\/strong\u003e Indoors\u003c\/li\u003e\n\n  \u003cli\u003e\n\n\u003cstrong\u003eEAN:\u003c\/strong\u003e 5905339044525\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\n\u003ch4\u003eWhat is the rated current of the Kanlux KS6 B16\/3?\u003c\/h4\u003e\n\u003cp\u003eThe Kanlux KS6 B16\/3 has a rated current of 16 A.\u003c\/p\u003e\n\n\u003ch4\u003eWhich tripping characteristic does the circuit breaker have?\u003c\/h4\u003e\n\u003cp\u003eThe circuit breaker has a B-type tripping characteristic and is therefore designed as a B16 circuit breaker.\u003c\/p\u003e\n\n\u003ch4\u003eHow many poles does the circuit breaker have?\u003c\/h4\u003e\n\u003cp\u003eThe Kanlux KS6 B16\/3 is a 3-pole device and is suitable for appropriately designed three-phase circuits.\u003c\/p\u003e\n\n\u003ch4\u003eWhat is the breaking capacity of the circuit breaker?\u003c\/h4\u003e\n\u003cp\u003eThe circuit breaker has a breaking capacity of 6 kA at 230\/400 V AC.\u003c\/p\u003e\n\n\u003ch4\u003eHow is the Kanlux KS6 B16\/3 mounted?\u003c\/h4\u003e\n\u003cp\u003eThe circuit breaker is mounted on a standardized 35 mm DIN rail and requires three modular spaces in the distribution board.\u003c\/p\u003e","brand":"Kanlux S.A.","offers":[{"title":"Default Title","offer_id":50521916178762,"sku":"SW657","price":10.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0918\/9602\/1322\/files\/sw657556c3edbd50af_15cc7dc85cf0.webp?v=1784800266","url":"https:\/\/saasil.de\/en\/products\/b16-3-sicherungsautomat-leitungsschutzschalter-b16-a-sicherung-automat-3-polig-4452","provider":"Saasil","version":"1.0","type":"link"}